7–2

Configuration: Scanner Control, Primary Match Table, Discrete I/O

Publication 2755-833

Laser Light (Scanners A and B)

Field Type Options

Select

On
Triggered
Off

Determines whether the Scanner A laser is on continuously, turns on
and off with the trigger, or is off regardless of the trigger. Use
triggered mode with slower package rates to extend the life of your
laser.

This parameter also affects Scanner B when it is set to operate in
coordinated mode with Scanner A. See Scanning Mode under
Scanner B Control.

On

The scanner scans continuously.

Triggered

The scanner scans only when receiving a trigger
from a package detector, host, or internal timer. The
scanner continues scanning until an end trigger
condition occurs.

Off

Turns the scanner laser off. Use this setting as a
safety precaution during decoder maintenance or
troubleshooting.

Important: It is important that you understand the following terms
before proceeding.

valid scan

valid symbol

valid read

valid package

no-read

See Glossary for definitions.

Decode Mode

Field Type Options

Select

Continuous
Continuous/Unique
Package Detect
Host
Internal Timer

Determines how the decoder starts and stops decoding. This
parameter affects Scanner A, or Scanner A and B when both are
operating in coordinated mode. (See Scanning Mode under Scanner
B Control.)