15–53

ASCII Host Commands

Publication 2755-833

HC - Configure Host Communications

Command Format:

HCaaannnssspppfr

Function:

Configures host communication parameters.

Parameters:

aaannnssspppfr

Command
Parameter

Parameter Function

Valid Values

aaa

ACK (Acknowledge) character

ASCII decimal value
000 to 254
255 = None

nnn

NAK character
(Negative Acknowledgement)

ASCII decimal value
000 to 254
255 = None

sss

Start scan character A

ASCII decimal value
000 to 254
255 = None

ppp

Stop scan character A

ASCII decimal value
000 to 254
255 = None

f

Large buffer enable

1=Yes, 0=No

r

Send Message to Host

0 = At end of Trigger
1= Immediately after
Valid Package

Response:

= rr <end>