Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 241
Advertising
15–53
ASCII Host Commands
Publication 2755-833
HC - Configure Host Communications
Command Format:
HCaaannnssspppfr
Function:
Configures host communication parameters.
Parameters:
aaannnssspppfr
Command
Parameter
Parameter Function
Valid Values
aaa
ACK (Acknowledge) character
ASCII decimal value
000 to 254
255 = None
nnn
NAK character
(Negative Acknowledgement)
ASCII decimal value
000 to 254
255 = None
sss
Start scan character A
ASCII decimal value
000 to 254
255 = None
ppp
Stop scan character A
ASCII decimal value
000 to 254
255 = None
f
Large buffer enable
1=Yes, 0=No
r
Send Message to Host
0 = At end of Trigger
1= Immediately after
Valid Package
Response:
= rr <end>
rr =
response code
<end> =
end of message control code
Advertising