Configuration: AUX and LCD Display Parameters

Publication 2755-833

0

5

STS= 00H

TNS

High Byte

Low Byte

MSB

LSB

1

3

2

8

CMD= 08H

Display Message at AUX Terminal (900H)

Command Address = 900H

4

7

”T”

”S”

10

9

”R”

”A”

12

11

” ”

”T”

14

13

”O”

”J”

15

”!”

”B”

6

When the host sends this command to the decoder, the message
displays on the LCD at the beginning of the line in position 01. The
message remains on the display until it is overwritten by another
message or data.

Remember, the LCD can only display 20 or 40 characters depending
on whether scrolling is enabled. Messages that are longer than 20 or
40 characters will be truncated.

If the PCCC (900H) command is sent without a message defined, the
decoder displays the Default Prompt Message instead.

How Scrolling Affects the Display of Host Messages

Scrolling affects the placement of host messages (and default prompt
messages) on the LCD Display. When scrolling is disabled, each new
message overwrites the last message. When scrolling is enabled, new
messages display on line 2, scrolling the previous message up to line
1.

The following example shows how the LCD handles the host
messages ”START JOB” and ”END JOB” when scrolling is disabled
and enabled.

Scrolling Disabled (Default)

Host message scrolls up to line 1

New host message displays on line 2

Host message displays on line 2

Scrolling Enabled

START JOB

Host message displays

1

21

20

40

1

20

40

1

1

20

20

1

1

20

20

21

New host message over-
writes
previous host message.

1 Line x 40 Character Display

2 Line x 20 Character Display

END JOB

START JOB

START JOB

END JOB