Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 178

Advertising
background image

13–9

Configuration: AUX Terminal Data Entry

Publication 2755-833

AUX Terminal Screen

Decoder Operations

Enter Carton Data:

no-read

Package 1

Sends Default Prompt Message to AUX Terminal

12345

Host Recieves

no-read

Packag

12345

1

1

Keyboard enabled for package 1 no-read.

Example 2: What happens if you have not completed entering
the data at the keyboard and the next package arrives?

If the next package is a valid read, it will be sent to the discretes I/O
and the host. The package count will increment. This will continue
with each subsequent valid read. When the manual data entry is
complete, it will be sent to the host with the package count of the last
package read.

AUX Terminal Screen

Decoder Operations

Enter Carton Data:

no-read

Package 1

Sends Default Prompt Message to AUX Terminal

1234

Host Recieves

no-read

Package C

1

Package 2

12345

Not completed before package 2 arrives.

Keyboard enabled for package 1 no-read.

Data entry started.

76543

76543

2

Enter Carton Data: 12

Data entry continues.
Not complete before package 3 arrives

Package 3

24678

24678

Data entry complete.

3

3

If the next package (or any of the packages processed before the
manual data entry is completed) is a no-read, the decoder will send
only a single message. The opportunity for entering data for
additional no-reads that occurred during manual data entry will be
lost. In other words, if you can enter data manually more quickly
than no-reads occur, then you will lose no data. If two no-reads occur
before you have completed entering data for the first, then you will
have no opportunity to enter data for the second no-read in the
sequence.

Advertising