Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 87

Advertising
background image

6–14

Configuration: Symbology

Publication 2755-833

Decode Direction (Scanner A or B) (Pharma-Code Decoders Only)

Field Type Options

Select

Forward
Reverse

Sets the direction the decoder uses to decode a scanned label.
Direction values are either Forward or Reverse. The default is
Forward.

The decoder uses the decode direction to determine the least
significant bar of a symbol. The examples below show how a
Pharma-Code label is decoded depending on the direction.

Example 1: The decode direction is set to forward. The decode
direction fixes the position of the least significant bar (regardless of
scan direction). The decoded value is 94.

94

Least Significant Bar

Most Significant Bar

Decode Direction = Forward
Decoded Value = 94

Scan Direction

Decode Direction

Example 2: The decode direction is set to reverse. The decode
direction fixes the position of the least significant bar. The decoded
value is 125.

125

Most Significant Bar

Least Significant Bar

Decode Direction = Reverse
Decoded Value = 125

Scan Direction

Decode Direction

Wide to Narrow Bar Ratio (Pharma-Code Decoders Only)

Field Type Options

Edit

2 through 4 (2)
Midrange

Specifies the minimum ratio of the widest bar to the narrowest bar
within a symbol.

Valid settings are 2 to 4, or midrange. The default is 2. The default
value for this parameter has been optimized for most
applications, and it is unlikely you will ever have a reason to
change it.

If the setting is 2 to 4, the decoder will reject symbols whose wide to
narrow bar ratio is less than the parameter setting.