Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 248

15–60
ASCII Host Commands
Publication 2755-833
IM - Configure Scanner A Source Identifier
Command Format: I
Mlstring
Function:
Defines a source identifier for Scanner A.
Source identifiers are included in messages sent
to the host. They identify whether the data was
scanned (by Scanner A or B) or entered at the
AUX terminal.
NOTE: This command is valid only for dual
head decoders.
Parameters:
lstring
Command
Parameter
Parameter Function
Valid Values
l
Length of source identifier
0 to 4
①
string
Characters in source identifier
Up to 4 characters
① A zero length string will disable the source identifier.
Response:
= rr <end>
rr= response code
<end> = end of message control
code
Example:
Command:
I
M4SCNA
Parameters:
4SCNA
Command
Parameter
Parameter Function
Values
l
Length of source identifier
4
String
Characters in source identifier
SCNA
Response:
= 00LF
00 = command complete
response code
LF = end of message control
code for Line Feed