Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 247

Advertising
background image

15–59

ASCII Host Commands

Publication 2755-833

IX - Configure AUX Terminal Source Identifier

Command Format: I

Xlstring

Function:

Defines a source identifier for the AUX port
terminal. Source identifiers are included in
messages sent to the host. They identify whether
the data was scanned (by Scanner A or B) or
entered at the AUX terminal.

Note: This command only applies when the
AUX port is set for manual data entry
operations.

Parameters:

lstring

Command
Parameter

Parameter Function

Valid Values

l

Length of source identifier

0 to 4

String

Characters in source identifier

Up to 4 characters

① A zero length string will disable the source identifier.

Response:

= rr <end>

rr =

response code

<end> =

end of message control code

Example:

Command:

I

X3AUX

Parameters:

AUX

Command
Parameter

Parameter Function

Values

l

Length of source identifier

3

String

Characters in source identifier

AUX

Response:

= 00LF

00=

command complete
response code

LF=

end of message control code
for Line Feed

Advertising