Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 238

Advertising
background image

15–50

ASCII Host Commands

Publication 2755-833

SR - Set Search and Replace Rule for Host Message Fields

Command Format:

SRnnmmsccbbffapppllstringllstring

Function:

Set parameters for the host message replacement
rules.

Parameters:

nnmmsccbbffapppllstringllstring

Command

Parameters

Parameter Function

Valid Values

nn

The number of the Search and
Replace Rule

01 to 16

mm

The host message field number

00=All or 01 to 16

s

Source

1=Scanner A
2=Scanner B
3=A|B
4=Aux

cc

Symbology

01=Code 39
02=Interleaved 2-of-5
03=Codabar
04=UPC–A
05=UPC–E
06=EAN–8
07=EAN–13
08=Code 128
09=Pharma–Code
16=Any

bb

Symbol number

00=All or 01 to 16

ff

Minimum field length

00 to 64

a

Alignment

0=Right
1=Left

ppp

Fill character

000 to 255
(000= No alignment)

ll

Length of search pattern string

00=Empty or 01 to 24

string

Search pattern string

up to 24 characters

ll

Length of replace pattern string

00=Empty or 01 to 24

String

Replace pattern string

up to 24 characters

Response:

= rr <end>

rr =

response code

<end> =

end of message control code

Advertising