Mf - configure host message format – Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 245
Advertising
15–57
ASCII Host Commands
Publication 2755-833
MF - Configure Host Message Format
(continued)
Example:
Command:
MF1101110094042100
Parameters:
1101110094042100
Command
Parameters
Parameter Function
Values
a
Send bar code data?
1=Yes
b
Send package count?
1=Yes
c
Send bar code symbology?
0=No
d
Send source identifier?
Ignored
①
e
Send header message?
Ignored
①
f
Send no-read message?
Ignored
①
g
Expand UPC-E?
0=No
hhh
Label delimiter character
094 = ^ character
iii
Start character
042 = * character
j
End message control character
1 = CR
k
Transmission check method
0 = None
l
Send performance indicators?
0 = No
Response:
= 00CR
00 = command complete
response code
CR= end of message control
code for Carriage Return