Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 275
16–10
PCCC Host Commands
Publication 2755-833
1
3
0
2
STS= 00H
TNS
High Byte
Low Byte
MSB
LSB
Reply
CMD Reply = 48H
5
1
3
2
4
0
STS= 00H
Command Address = 600H through 639H,640H, 641H
TNS
High Byte
Low Byte
LSB
CMD= 08H
Execute Decoder Function
MSB
If you send a command with an invalid address, the reply returns a
status code of 10H (invalid address).
To set the current configuration to the factory defaults, send this
command:
2
4
0
5
1
3
STS= 00H
Command Address = 633H
TNS
High Byte
Low Byte
MSB
LSB
CMD= 08H
Set Decoder Configuration to Defaults
To save the current configuration and restart the decoder, send this
command:
5
1
3
2
4
0
STS= 00H
Command Address = 632H
TNS
High Byte
Low Byte
MSB
LSB
CMD= 08H
Save Configuration and Restart Decoder
To clear output counter 4 to all zeros, send this command:
5
1
3
2
4
0
STS= 00H
Command Address = 610H
TNS
High Byte
Low Byte
MSB
LSB
CMD= 08H
Clear Output Counter 4