Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 209
![background image](/manuals/580788/209/background.png)
15–21
ASCII Host Commands
Publication 2755-833
IF - Configure Scanner A Package Detect Filter and Sense
Command Format: I
Ff
Function:
Enables or disables the 15 ms input filter and
determines the sense of the package detect signal
for Scanner A.
Parameters:
f =
disable or enable filter/select sense.
Command
Parameter
Parameter
Function
Valid Values
f
Enable or disable
filter/select sense
0=disable filter,
LO when package is present
1=enable filter,
LO when package is present
2=disable filter,
HI when package is present
3=enable filter,
HI when package is present
Response:
= rr <end>
rr =
response code
<end> =
end of message control code
Example:
Command:
I
F1
Parameters:
1
Command
Parameter
Parameter
Function
Value
f
Enable or disable
filter/select sense
1=enable filter,
LO when package is present
Response:
= 00CR
00
=
command complete
response code
CR =
end of message control code
for Carriage Return