ASCII Host Commands
Publication 2755-833
PR - Read Package Counter
Command Format:
PR
Function:
Returns the count maintained by the package
counter.
Parameters:
None
Response:
pppppp<end>= rr <end>
pppppp=
package count, up to
999999
<end>=
end of message control code
rr =
response code
<end>=
end of message control code
Example:
Command:
PR
Response:
000075LF = 00LF
000075=
number of packages read by
decoder
LF=
end of message code for
Line Feed
00=
command complete
response code
L=
end of message code for
Line Feed