Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 210

15–22
ASCII Host Commands
Publication 2755-833
BF - Configure Scanner B Package Detect Filter and Sense
Command Format:
BFf
Function:
Enables or disables the 15 ms input filter and
determines the sense of the package detect signal
for Scanner B.
NOTE: This command is valid only for dual
head decoders.
Parameters:
f =
disable or enable filter/select sense.
Command
Parameter
Parameter
Function
Valid Values
f
Enable or disable
filter/select sense
0=disable filter,
LO when package is present
1=enable filter,
LO when package is present
2=disable filter,
HI when package is present
3=enable filter,
HI when package is present
Response:
= rr <end>
rr =
response code
<end> =
end of message control code
Example:
Command:
BF1
Parameters:
1
Command
Parameter
Parameter
Function
Value
f
Enable or disable
filter/select sense
1=enable filter,
LO when package is present
Response:
= 00CR
00
=
command complete
response code
CR =
end of message control code
for Carriage Return