Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 212
Advertising
![background image](/manuals/580788/212/background.png)
15–24
ASCII Host Commands
Publication 2755-833
SW - Write Scanner Source to Match Code Table
Command Format:
SWab
Function:
Configures the source of an event.
Parameters:
ab
Command
Parameters
Parameter Function
Valid Values
a
Match code table entry number
1 through 8
b
Source of event
1=Scanner A
2=Scanner B
①
3=A|B
①
4=Illegal
5=A–B
①
① Applies only to Dual-Head Decoder.
Response:
= rr <end>
rr =
response code
<end> =
end of message control code
Example:
Command:
SW11
Parameters:
1
Command
Parameters
Parameter Function
Values
a
Match code table entry number
1
b
Source of event
1=Scanner A
Response:
= 00CR
00 =
command complete
response code
CR =
end of message control code
for Carriage Return.
Advertising