Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 225
Advertising
15–37
ASCII Host Commands
Publication 2755-833
SE - Set Extended Match Counters
Command Format:
SEnnnmmmmmm
Function:
Sets the value of extended count number nnn to
mmmmmm.
Parameters:
nnnmmmmmm
Command
Parameters
Parameter Function
Valid Values
nnn
The number of the Extended
match count
001 to 128
000 = All
mmmmmm
The value of the count
000000 to 999999
Response:
= rr <end>
rr =
response code
<end> =
end of message control code
Example:
Command:
SC012000036
Parameters:
012
Command
Parameters
Parameter Function
Values
nnn
The number of the Extended
match count.
012
mmmmmm
The value of the count
000036
Response:
= 00CR
00 =
command complete
response code
CR =
end of message control code
for Carriage Return.
Advertising