Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 225

Advertising
background image

15–37

ASCII Host Commands

Publication 2755-833

SE - Set Extended Match Counters

Command Format:

SEnnnmmmmmm

Function:

Sets the value of extended count number nnn to
mmmmmm.

Parameters:

nnnmmmmmm

Command

Parameters

Parameter Function

Valid Values

nnn

The number of the Extended
match count

001 to 128
000 = All

mmmmmm

The value of the count

000000 to 999999

Response:

= rr <end>

rr =

response code

<end> =

end of message control code

Example:

Command:

SC012000036

Parameters:

012

Command

Parameters

Parameter Function

Values

nnn

The number of the Extended
match count.

012

mmmmmm

The value of the count

000036

Response:

= 00CR

00 =

command complete
response code

CR =

end of message control code
for Carriage Return.

Advertising