15–52
ASCII Host Commands
Publication 2755-833
SF - Set No-Read Replacement Strings
Command Format:
SFnnllstring
Function:
Set the No-Read Replacement Strings.
Parameters:
nnllstring
Command
Parameters
Parameter Function
Valid Values
nn
The number of the No-Read
Replacement String
01 to 16
ll
Length of the No-Read
Replacement String
00=Empty or 01 to 24
String
No-Read Replacement String
up to 24 characters
Response:
= rr <end>
rr = response code
<end> = end of message control
code
Example:
Command:
SF0207No–Read
Parameters:
02 07 No–Read
Command
Parameters
Parameter Function
Values
nn
The number of the No-Read
Replacement String
02
ll
Length of the No-Read
Replacement String
07
String
No-Read Replacement String
No–Read
Response:
= 00CR
00 =
command complete
response code
CR =
end of message control code
for Carriage Return.