Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 230
Advertising
15–42
ASCII Host Commands
Publication 2755-833
RP - Read All Extended Match Data (continued)
Example:
Command:
RP
Response:
001 M 03 01 001289 04 1289 CR
002 ...
...
128 M 03 01 001289 04 1289 CR
=00CR
Command
Parameters
Parameter Function
Values
nnn
The number of the Extended
match counts
064
a
Mode
M = Match Entry
s
Source
03=A|B
cc
symbology
01=Code 39
mmmmmm
The value of the count
001289
ll
Length of match string
04
string
Match string
1289
a
Mode
M = Match Entry
s
Source
3=A|B
cc
Symbology
01=Code 39
mmmmmm
The value of the count
000222
ll
Length of match string
04
string
Match string
6247
CR =
delimiter and/or end of
message control code for
Carriage Return
00 =
command complete
response code
CR =
end of message control code
for Carriage Return.