6–7

Configuration: Symbology

Publication 2755-833

This check differs from the one above, because instead of looking
at the number of transitions in the entire scan, this search only
considers the number of transitions contained within the symbol.
The decoder rejects the scan if the number of transitions does not
correspond to a selected specific length. It attempts to decode all
scans if no specific length is specified.

Code 128 FNC1 Character

Field Type Options

Edit

Valid ASCII
0 = None

Instructs the decoder to substitute any valid ASCII character for the
Code 128 FNC1 (Function 1) character. The default is 0 (None),
which means no substitution will take place.

The substitution will take place at the time of decoding, and before
any rules or match operations are applied. Users frequently substitute
the ASCII 29 character (CTRL ]) for the FNC1 character.

UPC-A

Field Type Options

Select

No
Yes

Enables/disables decoding of UPC-A labels. The default of No
disables decoding of this symbology. Select Yes to enable decoding.

UPC-A Supplements

Field Type Options

Select

None
2
5
2 or 5
Auto

Enables/disables decoding of UPC-A supplementary codes. The
default of None disables decoding of supplements for this
symbology. Options are: