15–35
ASCII Host Commands
Publication 2755-833
MW - Write Primary Match Code Table Entry (continued)
Example:
Command:
MW4102041289
Parameters:
4102041289
Command
Parameters
Parameter Function
Values
n
Match code table entry number
4
f
RESERVED
1
cc
Bar code symbology
02=Interleaved 2 of 5
ll
Length of match string
04
string
Match string
1289
Response:
= 00LF
00 =
command complete
response code
LF =
end of message control code
for Line Feed
CM - Clear Primary Output Counters
Command Format:
CMn
Function:
Clears the selected output counter to 0.
Parameters:
n =
output counter number 1 through 8
Response:
= rr <end>
rr =
response code
<end > =
end of message control code
Example:
Command:
CM3
Parameters:
3
= output counter #3.
Response:
= 00CR
00=
command complete
response code
CR =
end of message control code
for Carriage Return