background image

15–35

ASCII Host Commands

Publication 2755-833

MW - Write Primary Match Code Table Entry (continued)

Example:

Command:

MW4102041289

Parameters:

4102041289

Command

Parameters

Parameter Function

Values

n

Match code table entry number

4

f

RESERVED

1

cc

Bar code symbology

02=Interleaved 2 of 5

ll

Length of match string

04

string

Match string

1289

Response:

= 00LF

00 =

command complete
response code

LF =

end of message control code
for Line Feed

CM - Clear Primary Output Counters

Command Format:

CMn

Function:

Clears the selected output counter to 0.

Parameters:

n =

output counter number 1 through 8

Response:

= rr <end>

rr =

response code

<end > =

end of message control code

Example:

Command:

CM3

Parameters:

3

= output counter #3.

Response:

= 00CR

00=

command complete
response code

CR =

end of message control code