ASCII Host Commands
Publication 2755-833
AL - Autoload
Command Format:
ALabeestring
Function:
Load the match pattern into the next available
position set to autoload, checking first the
primary match table, and then the extended
match table. This is the equivalent of a manual
Autoload, except the data is supplied by the host
instead of a scanner.
Parameters:
abeestring
Command
Parameters
Parameter Function
Valid Values
a
Source
1=A
2=B
b
Symbology
1=Code 39
2=Interleaved 2-of-5
3=Codabar
4=UPC-A
5=UPC-E
6=EAN-8
7=EAN-13
8=Code 128
9=Pharma–Code
ee
Length of match string
00 to 32
string
Match string
Up to 32 ASCII
characters
Response:
= rr <end>
rr =
response code
<end>=
end of message control code