Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 214

Advertising
background image

15–26

ASCII Host Commands

Publication 2755-833

AL - Autoload

Command Format:

ALabeestring

Function:

Load the match pattern into the next available
position set to autoload, checking first the
primary match table, and then the extended
match table. This is the equivalent of a manual
Autoload, except the data is supplied by the host
instead of a scanner.

Parameters:

abeestring

Command

Parameters

Parameter Function

Valid Values

a

Source

1=A
2=B

b

Symbology

1=Code 39
2=Interleaved 2-of-5
3=Codabar
4=UPC-A
5=UPC-E
6=EAN-8
7=EAN-13
8=Code 128
9=Pharma–Code

ee

Length of match string

00 to 32

string

Match string

Up to 32 ASCII
characters

Response:

= rr <end>

rr =

response code

<end>=

end of message control code