15–61

ASCII Host Commands

Publication 2755-833

IB - Configure Scanner B Source Identifier

Command Format: I

Blstring

Function:

Defines a source identifier for Scanner B.
Source identifiers are included in messages sent
to the host. They identify whether the data was
scanned (by Scanner A or B) or entered at the
AUX terminal.

NOTE: This command is valid only for dual
head decoders.

Parameters:

lstring

Command
Parameter

Parameter Function

Valid Values

l

Length of source identifier

0 to 4

String

Characters in source identifier

Up to 4 characters

① A zero length string will disable the source identifier.

Response:

= rr <end>

rr =

response code

<end> =

end of message control code

Example:

Command:

I

B4SCNB

Parameters:

4SCNB

Command
Parameter

Parameter Function

Values

l

Length of source identifier

4

String

Characters in source identifier

SCNB

Response:

= 00LF

00

=

command complete
response code

LF=

end of message control code
for Line Feed