Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 48

Advertising
background image

4–9

Installing the Decoder

Publication 2755-833

Press “1” to proceed to the Symbology configuration screen. A
Caution screen will appear. This screen allows you to disable the
decoder’s optional output modules during configuration. It will
appear each time you select a configuration screen from the Select
Operations
menu while the outputs are enabled. More information
on this subject appears in Chapter 5. For now, press any key except

ESC

to continue configuration.

Note: Restarting the decoder by selecting “E” from the Select
Operations
menu after configuration will reactivate the output
modules.

At the Symbology configuration screen, we suggest resetting the
decoder to assure that you are starting from a default configuration.
To do so:

1. Press

ESC

to activate the command line at the bottom of the

screen.

2. Use the arrow keys to move the highlight to the “DEFAULT’

option.

3. Press

ENTER

(or

RETURN

on some keyboards).

4. Confirm your intention to reset the decoder to its default

configuration by answering yes to the confirmation prompt (press
“Y” in English).

Set Symbology Parameters

Enable the symbology (or symbologies) you would like to read by
using the arrow keys to move the highlight to the appropriate
position. Toggle through the available selections by pressing the
space bar. Press

ENTER

to accept each change.