14 - display and system configuration, Chapter objectives, Connect and set up aux terminal – Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 183: Display and system configuration, Chapter
![background image](/manuals/580788/183/background.png)
Chapter
14
Publication 2755-833
Display and
System Configuration
This chapter describes how to use the bar code decoder configuration
software to:
•
Display bar code strings
•
Display decoder performance indicators and counters
•
Reset status and counters
•
Restart the system
•
Select a new language option
•
Save the current configuration.
To use the built-in configuration menus and screens, you must first
connect a terminal to the RS-232 AUX port of the decoder.
Appendix D provides details on how to connect and setup each
terminal. The AUX port communication parameters are:
•
8 Data Bits
•
1 Stop Bit
•
9600 Baud Rate
•
Parity None
•
XON/XOFF Flow Control
Refer to Chapter 5 for information on getting started with the AUX
communication software.
Chapter Objectives
Connect and Set Up
AUX Terminal