15–46
ASCII Host Commands
Publication 2755-833
RS - Read Extended Match Set Status
Command Format:
RS
Function:
Reads the status of the extended match sets.
Parameters:
none
Response:
nnnnnnnn = rr <end>
rr =
response code
<end> =
end of message control code
Example:
Command:
RS
Response:
10010001 = 00CR
10010001 =
Sets 1, 4, and 8 enabled; all
others disabled.
00 =
command complete
response code
CR =
end of message control code
for Carriage Return.