6–5

Configuration: Symbology

Publication 2755-833

Codabar

Field Type Options

Select

No
Yes

Enables/disables decoding of Codabar labels. The default of No
disables decoding of this symbology. Select Yes to enable decoding.

Codabar Specific Lengths

Field Type Options

Edit Numeric 0 through 64 (0)

Sets length checking for Codabar labels. The default is 0, which
means the decoder does not check lengths.

You can specify up to 8 code lengths (maximum of 64 characters).
The code length includes the check character and the start and
stop characters
. If you specify a code length other than 0, the
decoder will only decode labels with the number of characters
specified.

Codabar Check Character

Field Type Options

Select

No
Yes

Controls whether the decoder is required to compute and verify a
code check character for Codabar bar codes. The code check
character ensures that the data is read correctly. The default is No,
which means the decoder treats all decoded characters as data.

The Codabar character is computed as a Modulus 16 sum of all
characters value as specified in the AIM specification USS-Codabar.

Include Codabar Check Character

Field Type Options

Select

No
Yes

Controls whether the Codabar check character computed by the
decoder is included in the message sent to the host. The default is
No, which means the Codabar check character is not sent.

Advertising