Upc-e, Upc-e supplements – Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 81

Advertising
background image

6–8

Configuration: Symbology

Publication 2755-833

None

Disables decoding of supplementary codes.

2

Enables decoding of 2 character supplementary codes.

5

Enables decoding of 5 character supplementary codes.

2 or 5

Enables decoding of 2 or 5 character supplementary codes.

Auto

Enables decoder to auto discriminate supplementary codes (None, 2 or 5) on label①

The Auto Selection allows you to mix labels without supplements with labels containing 2 or 5 digit
supplements. The supplements are often a different size than the primary symbol. Therefore, it is
critical that both the primary symbol and the supplement be present when the decoder is
triggered
. If the decoder does not detect the supplement, the primary symbol is sufficient to
produce a valid scan. The Auto selection is not recommended when the Decode Mode is set to
Continuous.

If you select 2, 5, or 2 or 5, the decoder must decode both the
primary label and the supplement to produce a valid scan.

UPC-E

Field Type Options

Select

No
Yes

Enables/disables decoding of UPC-E labels. The default of No
disables decoding of this symbology. Select Yes to enable decoding.

UPC-E Supplements

Field Type Options

Select

None
2
5
2 or 5
Auto

Enables/disables decoding of UPC-E supplementary codes. The
default of None disables decoding of supplements for this
symbology. Options are:

None

Disables decoding of supplementary codes.

2

Enables decoding of 2 character supplementary codes.

5

Enables decoding of 5 character supplementary codes.

2 or 5

Enables decoding of 2 or 5 character supplementary codes.

Auto

Enables decoder to auto discriminate supplementary codes (None, 2 or 5) on label①

The Auto Selection allows you to mix labels without supplements with labels containing 2 or 5 digit
supplements. The supplements are often a different size than the primary symbol. Therefore, it is
critical that both the primary symbol and the supplement be present when the decoder is
triggered
. If the decoder does not detect the supplement, the primary symbol is sufficient to
produce a valid scan. The Auto selection is not recommended when the Decode Mode is set to
Continuous.

If you select 2, 5, or 2 or 5, the decoder must decode both the
primary label and the supplement to produce a valid scan.