2708-dh5 attended workstations – Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 318

Advertising
background image

Setting Up Terminals

D–6

Publication 2755-833

Follow these steps if using one of the Allen-Bradley 2708-DH5
Attended Workstations:

1. Construct a cable to connect the decoder to the COM1 port of the

2708-DH5 terminal. Use a Belden 8303, Alpha 45123, or
equivalent type of cable. Use the following connector pinouts:

2
3
7

3
2
5

C

B

D

NEMA NEMA

Type 1

Type 4

9-pin Female

Decoder

Terminal

Male 19-pin NEMA Type 4 or Female
25-pin D Shell Connector

2. Plug terminal into power supply.

3. Power on terminal.

4. Select Network Menu (option 1) and set the following

parameters:

Terminal Number = 0

Terminal Type = Normal

The rest of the network parameters are not applicable.

5. Select Comm Port Menu (option 2) and set the following

parameters:

Comm Mode

XON/XOFF

Comm Baud Rate =

9600

Comm Data Bits =

8

Comm Parity =

None

Comm Stop Bits =

1

Comm CRLF =

Disabled

Comm Echo =

Disabled

Comm Handshake =

Disabled

The rest of the parameters are not applicable.

6. You are now ready to configure the decoder. See Chapter 5.

2708-DH5 Attended
Workstations

Advertising