2708-dh5 attended workstations – Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 318

Setting Up Terminals
D–6
Publication 2755-833
Follow these steps if using one of the Allen-Bradley 2708-DH5
Attended Workstations:
1. Construct a cable to connect the decoder to the COM1 port of the
2708-DH5 terminal. Use a Belden 8303, Alpha 45123, or
equivalent type of cable. Use the following connector pinouts:
2
3
7
3
2
5
C
B
D
NEMA NEMA
Type 1
Type 4
9-pin Female
Decoder
Terminal
Male 19-pin NEMA Type 4 or Female
25-pin D Shell Connector
2. Plug terminal into power supply.
3. Power on terminal.
4. Select Network Menu (option 1) and set the following
parameters:
Terminal Number = 0
Terminal Type = Normal
The rest of the network parameters are not applicable.
5. Select Comm Port Menu (option 2) and set the following
parameters:
Comm Mode
XON/XOFF
Comm Baud Rate =
9600
Comm Data Bits =
8
Comm Parity =
None
Comm Stop Bits =
1
Comm CRLF =
Disabled
Comm Echo =
Disabled
Comm Handshake =
Disabled
The rest of the parameters are not applicable.
6. You are now ready to configure the decoder. See Chapter 5.
2708-DH5 Attended
Workstations