13–10

Configuration: AUX Terminal Data Entry

Publication 2755-833

AUX Terminal Screen

Decoder Operations

Enter Carton Data:

no-read

Package 1

Sends Default Prompt Message to AUX Terminal

12

Host Recieves

no-read

Package C

1

no-read

Package 2

no-read

2

12345

2

Completed after package 2 arrives.

Keyboard enabled for package 1 no-read.

Data entry started.

The opportunity to enter data for the Package 2 no-read is lost.

Important: To process a no-read and guarantee that the package
count of the manually entered data corresponds to the scanned data,
prevent future triggers from occurring. You can configure a discrete
output for the no-read condition or a host message containing
”no-read” to prevent subsequent packages from being processed.

ASCII Commands

The Display Text Message (TM) command allows you to send a
message to the AUX terminal and optionally enable the AUX
terminal keyboard for
one entry.

The following TM command sends the message ”START JOB!” but
does not enable the keyboard.

TM010START JOB!

Message Text String = START JOB!

Length of Text String = 10

Keyboard Not Enabled = 0

Command Code = TM

When the host sends this command to the decoder, the text string
displays on the AUX terminal at the beginning of the line in position
01.

START JOB!

Messages that are longer than the size of the AUX terminal display
truncate.

Using ASCII and
PCCC Commands