Configuration: Host Message Format
Publication 2755-833
Send Decoder Performance
Field Type Options
Select
Yes
No
Controls whether the performance indicators for Scanners A and B
are included in the message sent to the host. The default is No, the
performance indicators are not sent to the host.
The performance indicator is a three digit value for DS units, and a
six digit value for DD units. The first three digits apply to Scanner
A, and the last three digits apply to Scanner B.
End Message
Field Type Options
Select
None
CRLF
CR
LF
ETX
CRETX
LFETX
CRLFETX
Defines an ASCII control code to terminate or end each message sent
to the host. The default is CRLF, which terminates each message
with a carriage return and line feed.
Default No-Read Message
Field Type Options
Edit Text
Any ASCII Character
String
(32 chars max)
Blank
Defines a 1 to 32 character no-read message to include in each
message sent to the host when a no-read occurs and a specific
no-read message has not been defined for that field (see below). The
default is Blank, which means a default no-read message string is not
defined. An example no-read message is NO-READ.