Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 161

Advertising
background image

11–7

Configuration: Host Message Format

Publication 2755-833

Send Decoder Performance

Field Type Options

Select

Yes
No

Controls whether the performance indicators for Scanners A and B
are included in the message sent to the host. The default is No, the
performance indicators are not sent to the host.

The performance indicator is a three digit value for DS units, and a
six digit value for DD units. The first three digits apply to Scanner
A, and the last three digits apply to Scanner B.

End Message

Field Type Options

Select

None
CRLF
CR
LF
ETX
CRETX
LFETX
CRLFETX

Defines an ASCII control code to terminate or end each message sent
to the host. The default is CRLF, which terminates each message
with a carriage return and line feed.

Default No-Read Message

Field Type Options

Edit Text

Any ASCII Character
String
(32 chars max)
Blank

Defines a 1 to 32 character no-read message to include in each
message sent to the host when a no-read occurs and a specific
no-read message has not been defined for that field (see below). The
default is Blank, which means a default no-read message string is not
defined. An example no-read message is NO-READ.