Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 199

Advertising
background image

15–11

ASCII Host Commands

Publication 2755-833

CC - Configure Code 39, I 2-of-5, Codabar Check Characters

Command Format:

CCabcdef

Function:

Enables or disables bar code check characters.

Parameters:

abcdef

a through f are Yes (1) and No (0) responses to
the following parameters (in sequence shown):

Command

Parameters

Parameter Function

Valid Values

a

Code 39 check character?

1=Yes, 0=No

b

Send Code 39 check character?

1=Yes, 0=No

c

I 2-of-5 check character?

1=Yes, 0=No

d

Send I 2-of-5 check character?

1=Yes, 0=No

e

Codabar check character?

1=Yes, 0=No

f

Send Codabar check character?

1=Yes, 0=No

Response:

= rr <end>

rr =

response code

<end> =

end of message control

code

Example:

Command:

CC111100

Parameters:

111100

Command

Parameters

Parameter Function

Values

a

Code 39 check character?

1=Yes

b

Send Code 39 check character?

1=Yes

c

I 2-of-5 check character?

1=Yes

d

Send I 2-of-5 check character?

1=Yes

e

Codabar check character?

0=No

f

Send Codabar check character?

0=No

Response:

= 00CR

00 =

command complete
response code

CR =

end of message control code
for Carriage Return.

Advertising