15–36
ASCII Host Commands
Publication 2755-833
CO - Clear All Primary Output Counters
Command Format:
CO
Function:
Clears the Primary Counters to zero.
Parameters:
None
Response:
= rr <end>
rr =
response code
<end>=
end of message control
code
Example:
Command:
CO
Response:
= 00CR
00 =
command complete
response code
CR =
end of message control code
for Carriage Return
CA - Clear Extended Match Counters
Command Format:
CA
Function:
Clears the value of the extended counts to zero.
Parameters:
None
Response:
= rr <end>
rr =
response code
<end> =
end of message control code
Example:
Command:
CA
Response:
= 00CR
00 =
command complete
response code
CR =
end of message control code
for Carriage Return