4–17

Installing the Decoder

Publication 2755-833

Figure 4.9 Connecting device to HOST port of NEMA Type 1
decoder

Allen-Bradley PLC Controller via:

Cat. No. 1771-DB BASIC Module

Any RS-232 or RS-422 ASCII Device

Cat. No. 1771-DA ASCII I/O Module
Cat. No. 2760-RB Flexible Interface Module
with Cat. No. 2760-SFC1/SFC2 Protocol Cartridge

Supported Host Devices

-

-

-

HOST

RS-232 /422 /485

SCANNER A SCANNER B

AUX

RS-232

① Construct your own cable using pinouts in Appendix E.

Pin

Abbreviation

Function

1

GND

Chassis Ground

2

TD

RS-232 Transmit Data (from decoder to host).

3

RD

RS-232 Receive Data (from host).

4

RTS

RS-232 Request to Send

5

CTS

RS-232 Clear to Send

6

DSR

RS-232 Data Set Ready

7

SIG GND

RS-232 Signal Common

9

SHLD

RS-485 Shield Ground

12

485 TERM

RS-485 Line Termination. Jumpers to 13.

13

485 A/TERM

RS-485 Line Termination. Jumpers to 12.

14

TxB+

RS-422(B) or RS-485(B) Transmit Data (from decoder to host).

15

TxA-

RS-422(A) or RS-485(A) Transmit Data (from decoder to host).

16

RxA ’-

RS-422 Receive Data (from host).

17

RxB ’+

RS-422 Receive Data (from host).

18

422 A/TERM

RS-422 Line Termination. Jumpers to 19.

19

422 TERM

RS-422 Line Termination. Jumpers to 18.

20

DTR

RS-232 Data Terminal Ready

The HOST port on the NEMA Type 4 decoder has a 19-pin (male)
connector and communicates over an RS-232, RS-422, or RS-485
communication line. Figure 4.10 shows host devices you can connect
to the HOST port of the NEMA Type 4 decoder.