Reset diagnostic counters, Read diagnostic status – Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 281

16–16
PCCC Host Commands
Publication 2755-833
Each diagnostic counter increments when the event occurs. The
Reset Diagnostic Counters command resets all counter values to zero
(0).
Reset Diagnostic Counters
The Reset Diagnostic Counters (CMD= 06H, FNC= 07) sets all
diagnostic counter values to zero (0). The command and reply
formats look like this:
0
STS= 00H
High Byte
Low Byte
MSB
LSB
1
3
2
4
CMD= 06H
Reset Diagnostic Counters Command
0
STS= 00H
High Byte
Low Byte
MSB
LSB
2
Reset Diagnostic Counters Reply
1
3
FNC=07H
CMD Reply = 46H
TNS
TNS
Read Diagnostic Status
The Read Diagnostic Status command (CMD= 06H, FNC= 03H)
returns seven diagnostic parameters in the reply:
Diagnostic Return Parameters
Parameter
Value
Bytes Size
Mode/Status
00
1 byte
Extended Type
EEH
1 byte
Interface Type
22H
1 byte
Processor Type
21H
1 byte
Series/Revision
22H (Series B, Revision C)
1 byte
Bulletin Number/Product Name
ASCII characters
11 bytes
Product Information
unused
8 bytes
The command and reply format for the Read Diagnostic Status
Command is: