Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 236

Advertising
background image

15–48

ASCII Host Commands

Publication 2755-833

DP - Configure Data Display Positions for AUX Terminal and LCD

Command Format:

DPdpp

Function:

Enables the display of specific data items on the
LCD and/or AUX port terminal starting at a
specific character position.

Note: Before data will display at the AUX
terminal, you must set the AUX port to manual
data entry mode (as described in Chapter 13).

Parameters:

dpp

Command
Parameter

Parameter

Function

Valid Values

d

Data item selector

A= Bar Code Data
B= Decoder Performance
C= Package Counter
D= No-Read Counter
1= Primary Counter 1
2= Primary Counter 2
3= Primary Counter 3
4= Primary Counter 4
5= Primary Counter 5
6= Primary Counter 6
7= Primary Counter 7
8= Primary Counter 8

pp

Character position

00, 01 - 80
00= Disable

Response:

= rr <end>

rr=

response code

<end>=

end of message control code

Example:

Command:

DPA01

Parameters:

A01

Command
Parameter

Parameter

Function

Values

d

Data item selector

A= Bar Code Data

pp

Character position

01

Response:

= 00LF

00

=

command complete
response code

LF

=

end of message control code
for Line Feed