15–48
ASCII Host Commands
Publication 2755-833
DP - Configure Data Display Positions for AUX Terminal and LCD
Command Format:
DPdpp
Function:
Enables the display of specific data items on the
LCD and/or AUX port terminal starting at a
specific character position.
Note: Before data will display at the AUX
terminal, you must set the AUX port to manual
data entry mode (as described in Chapter 13).
Parameters:
dpp
Command
Parameter
Parameter
Function
Valid Values
d
Data item selector
A= Bar Code Data
B= Decoder Performance
C= Package Counter
D= No-Read Counter
1= Primary Counter 1
2= Primary Counter 2
3= Primary Counter 3
4= Primary Counter 4
5= Primary Counter 5
6= Primary Counter 6
7= Primary Counter 7
8= Primary Counter 8
pp
Character position
00, 01 - 80
00= Disable
Response:
= rr <end>
rr=
response code
<end>=
end of message control code
Example:
Command:
DPA01
Parameters:
A01
Command
Parameter
Parameter
Function
Values
d
Data item selector
A= Bar Code Data
pp
Character position
01
Response:
= 00LF
00
=
command complete
response code
LF
=
end of message control code
for Line Feed