Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 244

15–56
ASCII Host Commands
Publication 2755-833
MF - Configure Host Message Format
Command Format:
MFabcdefghhhiiijkl
Function:
Configures the format of messages sent to the
host.
Parameters:
abcdefghhhiiijkl
a through g are Yes (1) and No (0) responses to
the following parameters (in sequence shown):
Command
Parameters
Parameter Function
Valid Values
a
Send bar code data?
1=Yes, 0=No
b
Send package count?
1=Yes, 0=No
c
Send bar code symbology?
1=Yes, 0=No
d
Send source identifier?
Ignored
①
e
Send header message?
Ignored
①
f
Send no-read message?
Ignored
①
g
Expand UPC-E?
1=Yes, 0=No
hhh
Label delimiter character
ASCII Decimal Value
000 to 254
255 = None.
iii
Start character
ASCII Decimal Value
000 to 254
255 = None.
j
End message control character
0 = CRLF
1 = CR
2 = LF
3 = ETX
4 = None
5 = CR ETX
6 = LF ETX
7 = CR LF ETX
k
Transmission check method
0=None
1=LRC
2=Checksum-LSB first
3=Checksum-MSB first
l
Send performance indicator?
1=Yes, 0=No
① These parameters retained for compatibility with existing decoders. The
presence of each string type indicates that the string should be sent.
Response:
= rr <end>
rr =
response code
<end>=
end of message control code