Installing power cord – Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 43

Advertising
background image

4–4

Installing the Decoder

Publication 2755-833

of 6 inches (152 mm) below the decoder to wire I/O modules and
to access the power entry/power switch

To mount the decoder, we recommend that you use four

1

/

4

inch (M6)

hex-head capscrews or bolts with flat and split lockwashers and nuts.
Select a bolt that equals the thickness of the mounting surface, plus
the thickness of the washers, plus at least

1

/

2

inch (12.7 mm) to

accommodate the mounting brackets of the decoder and the nut.

The NEMA Type 1 decoder has a standard IEC 320 power entry
connector.

Figure 4.3 shows the available power cord options for the NEMA
Type 1 decoder. Unless an alternate power cord is ordered, the
decoder is shipped with a 120 VAC terminated (3 prong) U.S. power
cord.

Figure 4.3 Power cord options for NEMA Type 1 decoder

Power Cord Options

0

1

Brown (Line)

Blue (Neutral)

Green/Y

ellow (Earth Ground)

Green (Earth Ground)

White (Neutral)

Black (Line)

IEC 320
Connector

ON/OFF

Power Switch

① 120 VAC, IEC 320 terminated (three prong) U.S. style power cord
(6 ft./1.83m). Default. Shipped with decoder unless otherwise specified.

② 240 VAC, IEC 320 three wire (U.S. Color Code) unterminated power cord
(6ft./1.83 m).

③ 240 VAC, IEC 320 three wire (European Harmonized Code) unterminated
power cord. (UL listing/CSA approval not applicable when this cord is used.)
( 8 ft. 2 in./2.5 m)

!

ATTENTION: Disconnect incoming power and make
sure the power switch on the decoder is in the off
position before connecting power cord to power
source.

The NEMA Type 4 decoder has a standard 3-pin power connector
with a separate ON/OFF toggle switch.

Installing Power Cord

Advertising