ASCII Host Commands
Publication 2755-833
HB - Configure Scanner B Start & Stop Characters
➀
Command Format:
HCsssppp
Function:
Configures Scanner B start and stop characters
for independent host triggering.
Parameters:
sssppp
Command
Parameter
Parameter Function
Valid Values
sss
Start character for Scanner B
ASCII decimal value
000 to 254
255 = None
ppp
Stop character for Scanner B
ASCII decimal value
000 to 254
255 = None
Response:
= rr <end>
rr =
response code
<end> =
end of message control code
Example:
Command:
HB035043
Parameters:
035043
Command
Parameter
Parameter Function
Values
sss
Start character for Scanner B
035 = # character
ppp
Stop character for Scanner B
043 = + character
Response:
= 00CR
00 =
command complete
response code
CR =
end of message control code
for Carriage Return
①
Implemented in Series B Revision C (and later) decoders.