APPENDIX B

49’1340 e

FlexPak 3000

B-7

ANLG OUT 2 SELECT (P.421)
Only available if the I/O Expansion Kit is installed.
Selects the signal used to drive analog output 2 (terminals 56 and 57 on the I/O Expansion board).
When the analog output is at its maximum value, the selected signal is at is full scale value.

Parameter Range:

See table below for parameter options.

Default Setting:

ZERO

Parameter Type:

Configurable

OIM Menu Path(s):

Input/Output - Analog I/O

Refer also to Parameters:

MAXIMUM CURRENT (P.007)

MOTOR HOT FLD AMPS (P.510)

MOTOR RATED ARM AMPS (P.008)
MOTOR RATED ARM VOLTS (P.009)

TOP SPEED (P.011)

Signal Selected

Full Scale Value

CML FEEDBACK (P.397)
CML REFERENCE (P.396)
CML ERROR (P.398)
SPD LOOP OUTPUT (P.299)

±

MOTOR RATED ARM AMPS * MAXIMUM CURRENT

100

SPD LOOP FEEDBACK (P.296)
SPD LOOP REFERENCE (P.295)
SPD LOOP ERROR (P.297)
SPEED RAMP OUTPUT (P.199)
SPEED RAMP INPUT TP (P.198)
SPD SOURCE SELECT OUT (P.193)
TRIM OUTPUT (P.197)
ANALOG TACH FEEDBACK (P.291)
PULSE TACH FEEDBACK (P.292)
OCL OUTPUT (P.848)

±

TOP SPEED

ARMATURE VOLTAGE (P.289)

±

MOTOR RATED ARM VOLTS

POWER OUTPUT

±

MOTOR RATED ARM VOLTS * MOTOR RATED ARM AMPS * MAXIMUM CURRENT

100

FIELD REFERENCE (P.590)
FIELD FEEDBACK (P.589)

MOTOR HOT FLD AMPS

OCL REFERENCE (P.845)

±

4095

OCL RAMP OUTPUT (P.846)
OCL FEEDBACK (P.847)
NETW IN REG 1 (P.905)
NETW IN REG 2 (P.906)
NETW IN REG 3 (P.907)
FULL SCALE
ZERO

0

ARM VOLTAGE GAIN ADJ (P.204)
Used to scale the armature voltage signal after it has been conditioned by the drive hardware.
In most cases, this input will be 1.000.

Parameter Range:

0.750 to 1.250

Default Setting:

1.000

Parameter Type:

Tuneable

OIM Menu Path(s):

Speed/Voltage Loop (SPD) - Speed/Voltage Loop (SPD) Feedback

WARNING

The incorrect setting of this parameter can cause an overspeed condition. This parameter must be set

by a qualified person who understands the significance of setting it. Set the value of this parameter

accurately per your application requirements. Failure to observe this precaution could result in bodily

injury.