Rockwell Automation FlexPak 3000 Power Module Version 4.2 User Manual

Page 55

Advertising
background image

DRIVE SETUP AND ADJUSTMENT

49’1340 e

FlexPak 3000

4-13

4.14.2 How to Enable/Disable Program Protection

To enable or disable program protection, PASSWORD must be selected at the Operator
Interface
menu. After pressing ENTER to confirm this selection, one of the following two
screens will appear depending on the current state of program protection.

Do you wish to enter the password to ENABLE
program protection?

NO

YES

$$

$$

Fault
Alarm
Interlock OK
Drive Ready
Running
Current Limit
Torque Limit

PROGRAM

KEYPAD MANUAL FORWARD

-OR-

Do you wish to enter the password to DISABLE
program protection?

NO

YES

$$

$$

Fault
Alarm
Interlock OK
Drive Ready
Running
Current Limit
Torque Limit

PROGRAM

KEYPAD MANUAL FORWARD

NOTE: Pressing ENTER or CANCEL while at one of these screens will display the Operator
Interface
menu.

Select YES. At the PASSWORD integer value screen: set the value to 55.

PASSWORD
+ 55
-10000 <-> 10000

$$

$$

Fault
Alarm
Interlock OK
Drive Ready
Running
Current Limit
Torque Limit

PROGRAM

KEYPAD MANUAL FORWARD

4.14.3 Memory Operations

The user can save current changes made to parameter values, restore the last saved
parameter values, or restore all parameters to their factory default value. Select Memory
Operations
from the Operator Interface menu to perform any of these operations.

FlexPak 3000 Main Menu

Operator Interface*

MEMORY SAVE - This choice saves the current changes ("runtime" RAM memory) of
parameter values to retentive memory. Changes to parameters effect the operation of the drive.
However, these changes are lost if the drive is powered down without saving the changes.

MEMORY RESTORE - This choice restores the last saved parameter values from retentive
memory to "runtime" memory.

RESTORE DEFAULTS - This choice restores factory default parameter values to "runtime"
memory.

Advertising