APPENDIX C

49’1340 e

FlexPak 3000

C-9

OCL ENABLE (P.849)

The status of the outer control loop (OCL). OFF indicates the OCL is disabled or held in reset (the drive
is not running). ON means it is operating.

Parameter Range:

ON,
OFF

OIM Menu Path(s):

Outer Control Loop (OCL) - OCL Test Points

Refer also to Parameters:

DIG IN 5 (P.499)

OCL FEEDBACK (P.847)

The feedback value of the outer control loop. It is displayed in OCL user-defined units.
See OCL LEADLAG LOW FREQ for the block diagram.

OIM Menu Path(s):

Outer Control Loop (OCL) - OCL Test Points

Refer also to Parameters:

OCL LEADLAG LOW FREQ (P.847)

OCL OUTPUT (P.848)

The output of the outer control loop in speed units. This is the OCL trim that is applied to the
speed/voltage control loop. See OCL PI LEAD FREQ for block diagram.

OIM Menu Path(s):

Outer Control Loop (OCL) - OCL Test Points

Refer also to Parameters:

OCL PI LEAD FREQ (P.809)

OCL RAMP OUTPUT (P.846)

The outer control loop reference ramp output in OCL user units. This is the OCL reference output after
OCL reference rounding and S-curve have been applied.
See OCL REF RAMP TIME for block diagram.

OIM Menu Path(s):

Outer Control Loop (OCL) - OCL Test Points

Refer also to Parameters:

OCL RAMP OUTPUT (P.846),

OCL REF RAMP TIME (P.802)

OCL REF ROUNDING (P.803),

OCL REFERENCE (P.845)

S-CURVE ROUNDING (P.014)

OCL REFERENCE (P.845)

The reference value for the outer control loop. Displayed in OCL user units.
See OCL REF RAMP TIME for block diagram.

OIM Menu Path(s):

Outer Control Loop (OCL) - OCL Test Points

Refer also to Parameters:

OCL RAMP OUTPUT (P.846),

OCL REF RAMP TIME (P.802)

OCL REF ROUNDING (P.803),

OCL REFERENCE (P.845)

POWER UNIT TYPE (P.795)

Indicates if the drives employs an S6R (regenerative) or an S6 (non-regenerative) power unit. If the
power unit type is S6 (non-regenerative), NEGATIVE CURRENT LIM will be automatically fixed to 0, and
REVERSE DISABLE fixed to ON (preventing reverse direction).

OIM Menu Path(s):

Drive Information