INTRODUCTION TO THE DRIVE

FlexPak 3000

49’1340 e

2-14

Moves the cursor left or right in parameter modification (value entry) screens

to allow digit selection for parameter value setting.
Left (

) accesses the Language Selection menu at any menu level but not

at parameter modification screens. See section 4.13 of this instruction

manual for further details on the Language Selection menu.
Right (

) accesses the Contrast Adjustment screen at any menu level but

not at parameter modification screens. See section 4.7 of this instruction

manual for further details on the Contrast Adjustment screen.

2.5.2.2 Drive Control Keys

These keys can be used to control the motor. They provide the user with the ability to start, jog,

select direction, select reference and control source. See figure 2.2

Selects where the control signals for the drive originate. "KEYPAD" (OIM

control), "TERMBLK" (terminal strip control) or "NETWORK" (network

communication board). The selection can only be changed when the drive is

not running. The state of this key (TERMBLK or KEYPAD, SERIAL or

NETWORK) is shown on the LCD directly above the key.

Keypad control uses the OIM buttons to control drive operations. The KEYPAD REF value

(displayed in MONITOR mode) is used as the drive reference.

Termblk control uses the reference at regulator board terminals (17-18 for Manual

Reference or 19-20 for Auto Reference) for the setpoint. It also uses the controls connected

to the terminal strip for control of drive operations. Reference Figure 3-8 for more details.

Network control can only be selected with a network communication board installed and when
the control signals and reference originate from the network board.

When the drive is configured as a current regulator (J15 = CURRENT), the control source can

only be set to TERMBLK.

The AUTO/MANUAL key determines which drive reference source will be

used when the CONTROL SOURCE SELECT is set to KEYPAD. The state

of this key (AUTO or MANUAL) is shown on the LCD directly above the key.

AUTO will use the signal at regulator board terminals 19 and 20 (see figure 3.8). The type of

signal accepted at these terminals is determined by the position of hardware jumpers J10

and J12 (see Figure 4-1).

MANUAL will use the KEYPAD REF from the OIM as the drive reference. When CONTROL

SOURCE SELECT is not set to KEYPAD REF, the preset state of the reference mode is

shown above the key (determined from the selected control source). When the drive is

configured as a current regulator (J15 = CURRENT), AUTO/MANUAL is fixed in the AUTO

mode.

FORWARD

--------------
REVERSE

Selects the direction of rotation when the drive at rest, or dynamically

changes the direction of rotation (regenerative drives only) when the drive in

operation. This key is active only when in KEYPAD control. This key also

affects the direction of rotation for JOG. The FORWARD/REVERSE key is

fixed to forward for any of these conditions: when the REVERSE DISABLE

parameter is set to ON (for regenerative drives); when the drive is non-

regenerative; when an A-C tach is used; and when a pulse tach with

quadrature disabled is being used. The state of the controlling input is shown

on the LCD directly above the key.

CONTROL

SOURCE

SELECT

AUTO

--------

MANUAL