Rockwell Automation FlexPak 3000 Power Module Version 4.2 User Manual

Page 188

Advertising
background image

APPENDIX E

FlexPak 3000

49’1340 e

E-4

Table E.1 - Fault Codes (Continued)

CODE

DISPLAY

DESCRIPTION

F00013 NETWORK

COMMUNICATION
TIMEOUT

Network Communications is missing or failed to communicate with
master. (

CONTROL SOURCE SELECT

=

NETWORK

)

Possible causes:

NETW CONNECT TYPE (P.910) was changed from BASIC to

FULL.

NETW DROP NUMBER (P.900) was changed.

Network Option cable connections are loose or not connected.

Network Option device failed or master communications failed.

F00014 REVERSED TACH

LEADS

The difference between the speed reference and speed feedback was
greater than

TACH LEAD FLT THRESH (P.227)

for the time

specified in

TACH LEAD FLT DELAY

(P.228)

.

Possible causes:

The motor armature leads are reversed.

The motor field leads are reversed.

The speed feedback leads are reversed.

There is an overhauling load

Improper drive tuning.

F00015 INVERTING FAULT

AVOIDED

The inverting fault

avoidance logic has detected conditions that could

have caused an inverting fault. The drive took action to avoid an actual
inverting fault.
See Parameter P.312 description for more information.

F00016 PHASE LOSS

The measured AC line voltage fell below 75% of the value specified by
NOMINAL AC LINE VOLTS (P.307).

F00030
F00030
to
F00041

SCR No. n
NOT OPERATING

The value of `n' indicates the SCR that is not operating;
n = 1-6, 11-16.

F00042 MULTIPLE SCRS

NOT OPERATING

One or more thyristor (SCR) is not carrying an equal load.
Possible causes:

Disconnected, loosely connected or damaged thyristor gating circuit.

Blown A-C line fuse(s).

Improper Current Minor Loop tuning.

Improper Speed/Voltage Loop tuning.

Failed thyristor.

F00060 SELF TUNING

FAULT

Self Tune aborted by external input.
Possible causes:

Operator stop asserted.

Drive interlock(s) open.

Drive fault became active.

F00061 SELF TUNING

FAULT

Non-zero speed feedback at self tune start.
Possible causes:

Incorrect speed feedback scaling or offset.

Overhauling load causing motor shaft rotation.

F00062 SELF TUNING

FAULT

Calculated armature inductance is out of range.
Possible causes:

Motor armature winding not connected or open circuit.

Blown inverting fault (DC) fuse.

Inverting fault breaker tripped.

Armature inductance too high, tune CML manually.

Advertising