APPENDIX B

FlexPak 3000

49’1340 e

B-12

DECELERATION TIME (P.002)

Selects the time it takes to decelerate from TOP SPEED to 0. Smaller changes in speed take
proportionately less time.
If TRIM MODE SELECT is set to PROPORTIONAL, this time value is modified by DRAW
PERCENTAGE OUT.

Parameter Range:

0.1 to 300.0 seconds

Default Setting:

5.0 seconds

Parameter Type:

Tuneable

OIM Menu Path(s):

Drive Reference - Drive Reference Ramp Quick Start

Refer also to Parameters:

DRAW PERCENTAGE OUT (P.196)

ANLG AUTO ZERO ADJ (P.102)

TOP SPEED (P.011)

TRIM MODE SELECT (P.110)

RAMP STOP DECEL TIME (P.018)

DEVICENET POLL MSG (P.913)

Selects which predefined set of data will be part of the DeviceNet poll connection command/response
messages. The amount of data transmitted in the CONTROL ONLY poll message type allows greater
network density and performance. The larger amount of data transmitted in the CONTROL+CONFIG
poll message type allows some degree of drive configuration but decreases the network scan rate.

Parameter Range:

CONTROL ONLY,

CONTROL+CONFIG

Default Setting:

CONTROL ONLY

Parameter Type:

Configurable

If the AutoMax Network Communication board is being used, this parameter has no effect.

DIG IN 0 SELECT (P.428)

Determines which function is controlled by DIG IN 0 (Regulator board terminal 12).

Parameter Range:

1 = BRUSH WEAR,

2 = JOG SPEED SELECT

3 = OCL ENABLE

Default Setting:

1

Parameter Type:

Configurable

OIM Menu Path(s):

Additional Parameters

Refer also to Parameters:

DIG IN 0 (P.490)

The functions can be:

BRUSH WEAR

: To use this option, a brush wear indicator device must be installed. If the input is

OFF

,

the

MOTOR BRUSH WEAR LOW

alarm is generated.

JOG SPEED SELECT

: The input determines whether

JOG SPEED

1 (P.012) or

JOG SPEED

2 (P.017) will

be used when the drive is jogging.

OCL ENABLE

: Enables the outer control loop if

CONTROL SOURCE SELECT

is not set to

NETWORK

and if

the I/O Expansion kit is not installed. If an I/O Expansion kit is installed, the outer control loop enable
signal is digital input 5.

OCL ENABLE

* BRUSH WEAR

JOG SPEED SELECT

Network OCL Enable

Regulator board

Digital Input (term. 12)

NETWORK

TERMBLK

*KEYPAD

CONTROL

SOURCE

SELECT

OFF

Not Running

Running

Drive

Status

(OCL ENABLE)

OCL enable

P.849

P.000

I/O Expansion Kit

I/O Expansion

Digital Inputs (terminal 64)

(DIG IN 5)
P.499

(DIG IN 0)
P.490

disable

DIG IN 0 SELECT
P.428

SERIAL

Installed

Not Installed