APPENDIX G

49’1340 e

FlexPak 3000

G-5

Table G.1 - User Quick Reference Table for Input Parameters (continued)

Par.

Parameter

Parameter Selection /

Pg Initial Factory

User Data

No.

Adjustment Range

B-

Setting

Date

Setting

Digital Outputs Set-up (on I/O card)

409

DIG OUT 1 SELECT

LEVEL DETECT 1 OUTPUT

LEVEL DETECT 2 OUTPUT

IN CURRENT LIMIT

DRIVE READY

NETW COMM STATUS

NETW IN REG 1

NETW IN REG 2

NETW IN REG 3

13

LEVEL

DETECT 1

OUTPUT

410

DIG OUT 1 CONTACT TYP

NORMAL OPEN

NORMAL CLOSED

13

NORMAL

OPEN

411

DIG OUT 2 SELECT

LEVEL DETECT 1 OUTPUT

LEVEL DETECT 2 OUTPUT

IN CURRENT LIMIT

DRIVE READY

NETW COMM STATUS

NETW IN REG 1

NETW IN REG 2

NETW IN REG 3

14

LEVEL

DETECT 2

OUTPUT

412

DIG OUT 2 CONTACT TYP

NORMAL OPEN

NORMAL CLOSED

13

NORMAL

OPEN

Analog Inputs / Outputs (on I/O card)

413

ANLG IN 1 SIG TYPE

0-10V,

±10V

4-20 mA,

10-50 mA

3

±10 V

414

ANLG IN 1 ZERO ADJ

-200 - 200

3

0

415

ANLG IN 1 GAIN ADJ

0.750 - 2.250

3

1.000

416

ANLG IN 2 ZERO ADJ

-200 - 200

4

0

417

ANLG IN 2 GAIN ADJ

0.750 - 2.250

4

1.000

418

ANLG OUT 1 SELECT

CML FEEDBACK

CML REFERENCE

CML ERROR

SPD LOOP FEEDBACK

SPD LOOP REFERENCE

SPD LOOP ERROR

SPD LOOP OUTPUT

SPEED RAMP OUTPUT

SPEED RAMP INPUT TP

SPD SOURCE SELECT OUT

TRIM OUTPUT

ARMATURE VOLTAGE

ANALOG TACH FEEDBACK

PULSE TACH FEEDBACK

ZERO

FULL SCALE

POWER OUTPUT

OCL REFERENCE

OCL RAMP OUTPUT

OCL FEEDBACK

OCL OUTPUT

FIELD REFERENCE

FIELD FEEDBACK

NETW IN REG 1

NETW IN REG 2

NETW IN REG 3

5

ZERO