TABLE OF CONTENTS

FlexPak 3000

49’1340 e

II

4.0 Drive Setup and Adjustment

4-1...4-16

4.1

General ..................................................................................................................... 4-1

4.2

Test Equipment Needed ........................................................................................... 4-1

4.3

Power Off Inspection................................................................................................. 4-1

4.4

Motor Ground Check................................................................................................. 4-1

4.5

Jumper Settings........................................................................................................ 4-2
4.5.1 Set Regulator Type - J15 Jumper .................................................................. 4-3
4.5.2 Set Program Disable/Enable (OIM PROGRAM) - J16 Jumper....................... 4-4
4.5.3 Set Field Loss Enable/Disable (FIELD LOSS DETECT) - J20 ....................... 4-4
4.5.4 Set Tacho Loss / Open Arm. Enable/Disable (TACHO LOSS DET) - J26 ..... 4-4
4.5.5 Field Supply Jumper Connection (FIELD SUPPLY) - J21 .............................. 4-5
4.5.6 Manual Reference (MANUAL REF) - J19 Jumper.......................................... 4-5
4.5.7 Tachometer Voltage Range/Scale (TACH V RANGE/SCALE) - J14 / J11 ..... 4-5
4.5.8 Analog Auto Reference (AUTO REF) - J12 and J10 Jumpers ....................... 4-6
4.5.9 Armature Current Feedback Scaling (ARM I FB RB) - J18 Jumper ............... 4-6
4.5.10 Check position of the FILTER SELECT - J28 Jumper .................................. 4-6
4.5.11 Check position of the POWER INTERFACE- J30 Jumper............................. 4-6

4.6

Powering Up the Drive .............................................................................................. 4-7

4.7

OIM Screen Contrast Adjustment.............................................................................. 4-7

4.8

About the Main Menu ................................................................................................ 4-8

4.9

How to Access the Menus/Parameters ..................................................................... 4-8

4.10 Verify the Correct Direction of Motor Rotation......................................................... 4-10
4.11 Determination of DC Tachometer Lead Polarity...................................................... 4-10
4.12 Adjustments ............................................................................................................ 4-10

4.12.1 Perform Armature Voltage Zero Adjust...................................................... 4-11
4.12.2 Perform Analog Tachometer Zero Adjust .................................................. 4-11

4.13 Language Selection ................................................................................................ 4-11
4.14 Programming Features ........................................................................................... 4-12

4.14.1 Password (PASSWORD)............................................................................. 4-12
4.14.2 How to Enable/Disable Program Protection ................................................. 4-13
4.14.3 Memory Operations ..................................................................................... 4-13
4.14.4 Reset Clock ................................................................................................. 4-14
4.14.5 Define User Units ........................................................................................ 4-14

4.14.5.1 Define Speed Units...................................................................... 4-14
4.14.5.2 Define Load Units ........................................................................ 4-16

5.0 How to Change Parameter Values

5-1..5-4

5.1

Introduction ............................................................................................................... 5-1

5.2

Integer Value Entry Screen ....................................................................................... 5-1

5.3

Standard Choice Integer Value Entry Screen............................................................ 5-2

5.4

Selector Switch or Boolean Value Entry Screen........................................................ 5-4

6.0 Quick Start

6-1..6-10

6.1

Introduction ............................................................................................................... 6-1

6.2

About the Quick Start Exit Menu ............................................................................... 6-1

6.3

How to Step through Quick Start............................................................................... 6-1

6.4

Self Tuning................................................................................................................ 6-7
6.4.1

Self Tune Setup........................................................................................... 6-7

6.4.2

Execute Self Tuning .................................................................................... 6-8

6.5

Final Adjustments ................................................................................................... 6-10
6.5.1 Nominal A-C Line Adjustments .................................................................... 6-10

6.5.1.1 Perform Nominal AC-Line Frequency Adjust.................................. 6-10
6.5.1.2 Perform Nominal AC-Line Volts Adjust........................................... 6-10

Advertising