INTRODUCTION TO THE DRIVE

49’1340 e

FlexPak 3000

2-11

FlexPak 3000 Main Menu

!!

Quick Start

Drive Reference

Speed/Voltage Loop (SPD)

#

Current Minor Loop (CML)

PROGRAM

KEYPAD

MANUAL

FORWARD

Pressing this key will display the following screen:

MOTOR SPEED

0

RPM

ARM VOLTS

0

VOLTS

MOTOR LOAD

0

%FLA

KEYPAD REF:

0

RPM

!!

MONITOR

KEYPAD

MANUAL

FORWARD

This screen allows the user to change the drive's setpoint (KEYPAD REF) when the CONTROL

SOURCE SELECT is set to KEYPAD and the drive is in manual mode. Use the up/down arrow

keys to change the drive's setpoint. Pressing the ENTER key will save the setpoint to non-volatile

memory.

Pressing the PROGRAM/MONITOR key a second time will display motor speed (RPM) and

motor load (FLA):

0 RPM
0 %FLA

!!

MONITOR

KEYPAD

MANUAL

FORWARD

This screen does not allow the user to change the drive's setpoint (KEYPAD REF).

Pressing the PROGRAM/MONITOR key after the second time will re-display the previous

PROGRAM display (the first screen in this example).

Pressing the ENTER key will save the setpoint to non-volatile memory.
Pressing the CANCEL key when in monitor mode will return the OIM to the PROGRAM mode.
Table 2.6 lists drive parameters monitored and reported to the OIM.

Table 2.6 - Drive Monitor Capabilities

Monitor List

Selectable Engineering Units

Motor Speed

Percent, RPM, Units*

Arm Volts (Armature Voltage)

Volts

Motor Load (Armature Current)

Percent Full Load Amps (%FLA), Amps

TERMBLK REF, KEYPAD REF

or TORQUE REF**, NETWORK REF***

Percent, RPM, Units*

* Units: Indicates the user's option to select an engineering unit (6 characters maximum) for readout to display. A number

from 1 to 10,000 full scale can be assigned a meaningful value (e.g. FPM, Feet Per Minute, etc.). See "Define User
Units" in Section 4.

** When the drive is configured as a current (torque) regulator (J15 Hardware Jumper = CURRENT), the Control Source

Select (CSS) can only be set

to TERMBLK or NETWORK (if option is installed). In this case, TORQUE REF or

NETWORK REF is displayed. The units are the same as displayed for MOTOR LOAD.

** When the drive is configured as a speed or armature voltage regulator (J15 Hardware Jumper = SPEED),

the selected control source determines the reference source (TERMBLK REF or KEYPAD REF, or NETWORK REF).

*** Available with an optional Network Communication Board.