APPENDIX G

FlexPak 3000

49’1340 e

G-6

Table G.1 - User Quick Reference Table for Input Parameters (continued)

Par.

Parameter

Parameter Selection /

Pg Initial Factory

User Data

No.

Adjustment Range

B-

Setting

Date

Setting

419

ANLG OUT 1 SIG TYPE

0-10 V, ±10 V, 4-20 mA

6

±10 V

420

ANLG OUT 1 GAIN ADJ

0.500 - 1.300

5

1.000

421

ANLG OUT 2 SELECT

same as above for P.418

7

ZERO

422

ANLG OUT 2 GAIN ADJ

0.500 - 1.300

6

1.000

Frequency Inputs/Outputs (on I/O card)

423

FREQ IN ZERO

2.0 - FREQ IN FULL SCALE kHz

19

2.0 kHz

424

FREQ IN FULL SCALE

2.0 - 250.0 kHz

19

250.0 kHz

425

FREQ OUT SELECT

same as above for P.418

20

ZERO

426

FREQ OUT ZERO

2.0 - FREQ OUT FULL SCALE kHz

21

2.0 kHz

427

FREQ OUT FULL SCALE

2.0 - 250.0 kHz

20

250.0 kHz

428

DIG IN 0 SELECT

1 = BRUSH WEAR

2 = JOG SPEED SELECT

3 = OCL ENABLE

12

1

Field Regulator Set-up

500

ENHANCED FLD VOLT ADJ

0 - 180 (J21 = B-C)

14

84

501

FIELD ECONOMY DELAY

0 - 27 minutes

16

5 minutes

510

MOTOR HOT FLD AMPS

0.11 - installed supply rating
(4.00, 10.00, or 15.00 A)

30

0.1 A

511

FIELD ECONOMY REF

0 - 100%

16

0%

512

FIELD LOSS THRESHOLD

Armature voltage regulators:

50 - 100% of

MOTOR HOT FLD AMPS

(P.510)

Speed regulators: 0 - 100% of

MOTOR HOT FLD AMPS

(P.510)

17

60% of

MOTOR HOT

FLD AMPS

513

FIELD REF REGISTER

0 to MOTOR HOT FLD AMPS
(P.510)

18

MOTOR HOT

FLD AMPS

514

FIELD PI PROP GAIN

0.01 - 128.00

17

0.80

515

FIELD PI LEAD FREQ

0.01 - 56.50 rad/s

17

0.30 rad/s

516

FLD FEEDBACK GAIN ADJ

0.900 - 1.100

18

1.000

517

FIELD AUTO WEAKEN

DISABLED

ENABLED

17

DISABLED

518

FLD WEAKEN THRESHOLD

0 to 120% of
MOTOR RATED ARM VOLTS
(P.009)

19

95% of

MOTOR RATED

ARM VOLTS

519

FLD WEAKEN PROP GAIN

0.01 - 128.00

19

0.80

520

FLD WEAKEN LEAD FREQ

0.01 - 56.50 rad/s

18

0.30 rad/s

521

FIELD REF SELECT

1 = REGISTER

2 = ANALOG MAN TRIM REF

3 = ANALOG IN 1

4 = ANALOG IN 2.

18

1

587

FIELD DELTA HIGH LIM

0 - 180 degree

16

130 degree

Thyristor Firing check

600

OPEN SCR SENSITIVITY

0 - 100%

41

0%

601

OPEN SCR TRIP THRESH

800 - 4000

41

800

Advertising