J20 FIELD LOSS DETECT (P.597)

Indicates the position of hardware jumper FIELD LOSS DETECT, which enables or disables field current
loss detection. This jumper is only read on power-up.

OIM Menu Path(s):

Drive Information,

Field - Standard/enhanced Field Supply

J21 FLD SUPPLY JUMPER (P.598)

Indicates the position of hardware jumper FIELD SUPPLY JUMPER, which must be set according to the
jumper on the Enhanced Field Supply: positions A-C or B-C.

Parameter Range:

A-C,

B-C

OIM Menu Path(s):

Drive Information,

Field - Standard/enhanced Field Supply

Refer also to Parameters:

FLD Current Regulator (P.586)

This jumper only applies to the Enhanced Field Supply and does not effect the operation of the standard
or current regulator field supplies. This jumper is only read on power-up.
This parameter is not available if a Field Regulator Supply Kit is installed.

JOG RAMP OUTPUT (P.294)

An output that represents the jog reference value immediately after the jog ramp function.

OIM Menu Path(s):

Drive Reference - Drive Reference Test Points

LEVEL DETECT 1 OUTPUT (P.648)

Only available if the I/O Expansion kit is installed.
The output of the level detector 1 output. This signal drives digital output 1 (terminals 66 and 67 on the
I/O Expansion board) if DIG OUT 1 SELECT is set to LEVEL DETECT 1 OUTPUT.

Parameter Range:

ON,

OFF

OIM Menu Path(s):

Input/Output - Level Detectors

Refer also to Parameters:

DIG OUT 1 SELECT (P.409),

LEVEL DETECT 1 THRESH (P.603)

LEVEL DETECT 1 DELAY (P.604)

ON when the input signal is greater than or equal to LEVEL DETECT 1 THRESH for longer than LEVEL
DETECT 1 DELAY.
OFF whenever the input signal is less than LEVEL DETECT 1 THRESH.
See LEVEL DETECT 1 SELECT for block diagram.

LEVEL DETECT 2 OUTPUT (P.649)

Only available if the I/O Expansion Kit is installed.
The output of the level detector 2 output. This signal drives digital output 2 (terminals 68 and 69 on the
I/O Expansion board) if DIG OUT 2 SELECT is set to LEVEL DETECT 2 OUTPUT.

Parameter Range:

ON,

OFF

OIM Menu Path(s):

Input/Output - Level Detectors

Refer also to Parameters:

DIG OUT 2 SELECT (P.411),

LEVEL DETECT 1 SELECT (P.602)

LEVEL DETECT 2 DELAY (P.607), LEVEL DETECT 2 THRESH (P.606)

ON when the input signal is greater than or equal to LEVEL DETECT 2 THRESH for longer than LEVEL
DETECT 2 DELAY.
OFF whenever the input signal is less than LEVEL DETECT 2 THRESH.
See LEVEL DETECT 1 SELECT for block diagram.