4.12.1 Perform Armature Voltage Zero Adjust

WARNING

The incorrect setting of this parameter can cause an overspeed condition. This parameter must be set
by a qualified person who understands the significance of setting it accurately. Verify that the value of
this parameter is accurate per your application requirements. Failure to observe this precaution could
result in bodily injury.

With the drive stopped, note the value of "ARMATURE VOLTAGE" (P.289). If the value is 0
then no further adjustments are required. If the value is other than 0 then adjust the ARM
VOLTAGE ZERO ADJ (P. 205) with a more positive number if the reading is a minus value,
or with a more negative value if the reading is positive. Note the value of ARMATURE
VOLTAGE (P.289) and continue to adjust the zero adjust parameter accordingly until the
feedback value reads 0. Record the final value in Table 4.1, section 4.5.

4.12.2 Perform Analog Tachometer Zero Adjust

WARNING

The incorrect setting of this parameter can cause an overspeed condition. This parameter must be set
by a qualified person who understands the significance of setting it accurately. Verify that the value of
this parameter is accurate per your application requirements. Failure to observe this precaution could
result in bodily injury.

With the drive stopped, note the value of "ANALOG TACH FEEDBACK" (P.291). If the value is
0 then no further adjustments are required. If the value is other than 0 then adjust the
"ANALOG TACH ZERO ADJ" (P.202) with a more positive number if the reading is a minus
value, or with a more negative value if the reading is positive. Note the value of "ANALOG
TACH FEEDBACK" (P.291) and continue to adjust the zero adjust parameter accordingly until
the feedback value reads 0. Record the final value in Table 4.1, section 4.5.

4.13

Language Selection

1. At any menu level, press the left arrow (

) key to access the Language Select menu.

This menu cannot be accessed at any parameter modification (value entry) screens.
This screen will allow you to select the language used on the display. The currently selected
language is displayed in the upper right of the menu screen. In the MONITOR mode,
pressing HELP displays status indicators in the selected language.

LANGUAGE SELECT

ENGLISH

ENGLISH

DEUTSCH
FRANCAIS

#

ESPANOL

$$

$$

Fault
Alarm
Interlock OK
Drive Ready
Running
Current Limit
Torque Limit

PROGRAM

KEYPAD MANUAL FORWARD

The following languages are available:

ENGLISH (Default)

DEUTSCH (German)

FRANCAIS (French)

ESPANOL (Spanish)

ITALIANO (Italian)

Code (Parameter Numbers)

"Code" allows the use of parameter numbers when interfacing with the OIM. See appendices B
and C for a cross-reference of "Code No." to parameter names.