Rockwell Automation FlexPak 3000 Power Module Version 4.2 User Manual

Page 190

Advertising
background image

APPENDIX E

FlexPak 3000

49’1340 e

E-6

Table E.1 - Fault Codes (Continued)

CODE

DISPLAY

DESCRIPTION

F00700

FACTORY
DEFAULTS
RESTORED

The parameter values stored in retentive memory were determined to
be invalid, factory default values have been restored. All parameter
values (including any factory set parameters) must be re-adjusted
based on your particular application's requirements before the drive is
operated. After all parameters have been set properly, a memory save
must be performed.
Possible causes:

Power loss during a prior memory save.

New or defective regulator board.

F00701

FAULT LOG
RESTORE FAILURE

The fault log information stored in retentive memory was determined to
be invalid, the fault log has been cleared.
Possible causes:

Power loss during a prior fault log save.

Defective regulator board.

F00702 KEYPAD REF

RESTORE
FAILURE

The keypad reference value stored in retentive memory was
determined to be invalid, the keypad reference has been set to the

MINIMUM SPEED

value.

Possible causes:

Power loss during a prior keypad reference save.

Defective regulator board.

F00703 OIM KEY

RESTORE
FAILURE

The OIM key states stored in retentive memory were determined to be
invalid, the

FORWARD/REVERSE

key has been set to

FORWARD

, the

AUTO/MANUAL

key has been set to

MANUAL

.

Possible cause: Defective regulator board.

F00800

INVALID FIELD
INSTALLED

Installed field supply is not supported by the regulator.
Possible causes:

Disconnected, loosely connected, or damaged field supply wiring.

Regulated field supply failure.

Defective regulator board.

F00801

FIELD FEEDBACK
OFFSET TOO HIGH

Regulated field supply feedback offset is too high.
Possible causes:

Disconnected, loosely connected, or damaged field supply wiring.

Regulated field supply failure.

Defective regulator board.

F01000
to
F01999

MICROBUS
FAULT

An error occurred on the Microbus.
Possible causes:

Electrical noise due to improper wiring practices or unsuppressed

brake coils, relays, or contactors.

Disconnected, loosely connected or damaged Microbus ribbon cable.

Defective regulator board.

F01000-F01799: Defective Microbus peripheral or defective

Regulator board.

F01810-F01816: A Microbus peripheral was found that is not

supported by the regulator software.

F00999
and
F02000
to
F03999

MICRO-
PROCESSOR
HW/SW FAULT

A microprocessor hardware or software fault occurred.
Possible causes:

Electrical noise due to improper wiring practices or unsuppressed

brake coils, relays, contactors.

Defective regulator board.

Advertising